Back to Top

1
Hi, Guest!

Hanna HI 9147 Dissolved Oxygen Meter For Aquaculture

Update Terakhir
:
05 / 12 / 2019
Min. Pembelian
:
0 Unit

Harga

CALL
Karya Mandiri Instrument Indonesia adalah supplier peralatan laboratorium baik eletronik maupun mekanik, serta berbagai macam instrument measurement, dengan didukung dari berbagai macam merk dari negara negara Eropa, US, dan beberapa negara di Asia seperti Korea, Japan dan Taiwan.

Detail Hanna HI 9147 Dissolved Oxygen Meter For Aquaculture


CALL:
A.WIHARTA
081294124885
085778084789
087784022201


Karya Mandiri Instrument indonesia
adalah supplier peralatan laboratorium baik eletronik maupun mekanik, serta berbagai macam instrument measurement, dengan didukung dari berbagai macam merk dari negara negara Eropa, US, dan beberapa negara di Asia seperti Korea, Japan dan Taiwan. Instrument yang kami sediakan seperti : Anemometer, Analitical Balance, Spectrophotometer, pHmeter, Laser survey, Micropipette, Peristaltic Pump, Flame photometer, Water bath heating cooling, Colorimeter, Water Strirer, Viscometer. Freezers, Refractometer, Polarimeter, Sound Level meter, Tachometer. Dll

Kami juga menerima jasa service dan kalibrasi untuk peralatan laboratorium sesuai kemampuan kami.

 

Designed specifically for aquaculture Galvanic DO probe Backlit LCD Automatic Temperature Compensation Manual salinity and altitude compensation Water-resistant HI 9147 is designed for aquaculture applications. This unit is unique among our family of DO meters as it is supplied with a galvanic probe. Unlike polarographic probes, galvanic DO probes require no conditioning time. When you need to measure multiple samples in a given period of time, pick it up and measure on demand. HI 9147 is a must have for DO sensitive organisms or high bio-load environments. Order Information: HI 9147-04 is supplied with HI 76409/ 4 probe with 4 m ( 13’ ) cable and spare membranes ( 2) , electrolyte solution ( 30 mL) , batteries, screwdriver and instructions. HI 9147-10 is supplied with HI 76409/ 10 probe with 10 m ( 32.8’ ) cable and spare membranes ( 5) , electrolyte solution ( 30 mL) , batteries, screwdriver and instructions. HI 9147-15 is supplied with HI 76409/ 15 probe with 15 m ( 49.2’ ) cable and spare membranes ( 5) , electrolyte solution ( 30 mL) , batteries, screwdriver and instructions. HI 9147-20 is supplied with HI 76409/ 20 probe with 20 m ( 65.6’ ) cable and spare membranes ( 5) , electrolyte solution ( 30 mL) , batteries, screwdriver and instructions. Range O2 0.0 to 50.0 mg/ L ( ppm) % Saturation O2 0 to 600 % Temperature -5.0 to 50.0° C ( 32.0 to 122.0º F) Resolution O2 0.1 mg/ L ( ppm) or 1% Temperature 0.1° C ( 1º F) Accuracy ( @ 20° C) O2 ± 1% of reading Temperature ± 0.2° C ( 1º F) ( excluding probe error) Calibration manual, in saturated air Temperature Compensation automatic, -5 to 50° C ( 23° F to 122° F) Salinity Compensation 0 to 4000 m ( resolution 100 m) Salinity Compensation 0 to 51 g/ L ( ppt) ( 1 g/ L resolution) Battery Type / Life 1.5V AAA ( 3) / approx. 1, 000 hours of continuous use without backlight Environment 0 to 50° C ( 32 to 122° F) ; RH max 95% non-condensing Dimensions 185 x 72 x 36 mm ( 7.3 x 2.8 x 1.4” ) Weight 450 g ( 15.9 oz.)

Tampilkan Lebih Banyak
Kontak Kami