Back to Top

1
Hi, Guest!

HI 9142 Manual Calibration Dissolved Oxygen Meter

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
0 Unit

Harga

CALL
Karya Mandiri Instrument Indonesia adalah supplier peralatan laboratorium baik eletronik maupun mekanik, serta berbagai macam instrument measurement, dengan didukung dari berbagai macam merk dari negara negara Eropa, US, dan beberapa negara di Asia seperti Korea, Japan dan Taiwan.

Detail HI 9142 Manual Calibration Dissolved Oxygen Meter


CALL:
A.WIHARTA
081294124885
085778084789
087784022201


Karya Mandiri Instrument indonesia
adalah supplier peralatan laboratorium baik eletronik maupun mekanik, serta berbagai macam instrument measurement, dengan didukung dari berbagai macam merk dari negara negara Eropa, US, dan beberapa negara di Asia seperti Korea, Japan dan Taiwan. Instrument yang kami sediakan seperti : Anemometer, Analitical Balance, Spectrophotometer, pHmeter, Laser survey, Micropipette, Peristaltic Pump, Flame photometer, Water bath heating cooling, Colorimeter, Water Strirer, Viscometer. Freezers, Refractometer, Polarimeter, Sound Level meter, Tachometer. Dll

Kami juga menerima jasa service dan kalibrasi untuk peralatan laboratorium sesuai kemampuan kami.

 

Automatic Temperature Compensation Affordable and efficient DO probe and carrying case included The ever increasing demand for instant on-site analysis results has created a need for innovative and rugged portable, waterproof meters. Field work can subject instrumentation to the inclemency of weather. Cold, rain, snow, dust and humidity can cause condensation to breech the housing. Once the housing has been compromised, the meter is susceptible to diminishing performance and life. The rugged, waterproof housing of the HI 9142 solves many of the problems of field use. Calibration is performed with HI 7040 zero oxygen solution, while 100% calibration is done in air. The polarographic probe ( HI 76407/ 4) is accurate to 0.3 ppm and is supplied with a 4 m ( 13' ) cable that allows measurements to be taken even in hard to reach places. Order Information: HI 9142 is supplied with HI 76407/ 4 probe with 4 m ( 13’ ) cable, 2 spare membranes, HI 7041S electrolyte solution ( 30 mL) , calibration screwdriver, batteries, instructions and rugged carrying case. HI 9142/ 10 is supplied with everything above but substitutes a 10 m ( 32.8’ ) probe cable for the 4 m. HI 9142/ 20 is supplied with everything above but substitutes a 20 m ( 65.6’ ) probe cable for the 4 m. Range O2 0.0 to 19.9 mg/ L ( ppm) Temperature -5.0 to 50.0º C ( 32.0 to 122.0º F) Resolution O2 0.1 mg/ L ( ppm) Temperature 0.1° C ( 1º F) Accuracy ( @ 20° C) O2 ± 1.5% F.S. Temperature ± 0.2° C ( ± 1º F) ( excluding probe error) Calibration manual, at one or two points ( zero and slope) Temperature Compensation automatic, 0 to 50° C ( 32 to 122° F) Probe HI 76407/ 4 polarographic DO probe with internal temperature sensor, DIN connector and 4 m ( 13’ ) cable Battery Type / Life 1.5V AAA ( 3) / approximately 1, 000 hours of continuous use Environment 0 to 50° C ( 32 to 122° F) ; RH max 95% Dimensions 185 x 72 x 36 mm ( 7.3 x 2.8 x 1.4” ) Weight 300 g ( 10.6 oz.)

Tampilkan Lebih Banyak
Kontak Kami