1
Hi, Guest!

  LOKASI :  Jakarta Timur

  AKTIVITAS :  18/10/2019

BAGIKAN :   

Bagikan :
Masukan Data Diri Anda
Nama harus diisi !
Email harus diisi !
Format email harus someone@example.com !
ALAT LAB MURAH :EBRO,DAVIS WEATHER STATION,HANNA INSTRUMENT,EXTECH,EUTECH,IKA,GE DRUCK,BOECO,BESTSCOPE,FLUKE,DWYER,HACH,KYORITSU,OHAUS,MEMMERT,HIOKI,SCHOOT,KETT

Alat Ukur Agen Industri Hioki 3194 Motor - Harmonic Hitester

Update Terakhir
:
26 / 06 / 2019
Min. Pembelian
:
1 Unit
Harga
CALL
Bagikan
:
Karya Mandiri Instrument Indonesia adalah supplier peralatan laboratorium baik eletronik maupun mekanik, serta berbagai macam instrument measurement, dengan didukung dari berbagai macam merk dari negara negara Eropa, US, dan beberapa negara di Asia seperti Korea, Japan dan Taiwan. Instrument yang kami sediakan seperti : Anemometer, Analitical Balance, Spectrophotometer, pHmeter, Laser survey, Micropipette, Peristaltic Pump, Flame photometer, Water bath heating cooling, Colorimeter, Water Strirer, Viscometer. Freezers, Refractometer, Polarimeter, Sound Level meter, Tachometer. Dll Kami juga menerima jasa service( Repair alat laboratorium/instrument, alat ukur, Alat kesehatan) dan kalibrasi untuk peralatan laboratorium sesuai kemampuan kami.

Info Produk dan Order Hubungi :
Mobile : 081294124885 // 085778084789 // 085104387311
Email   : karyamandiriinstrument@yahoo.com
Website : www. karyamandiri-instrument.com

Detail Jual Alat Ukur Agen Industri Hioki 3194 Motor - Harmonic Hitester

CALL:

A.WIHARTA

081294124885

085778084789

087784022201

 

Info Produk

Basic specifications
Measurement lines Single-phase 2-wire, single-phase 3-wire, three-phase 3-wire, and three-phase 4-wire systems
Number of channels Up to 3 channels from input channels 1 to 6, depending on 3194 wiring mode
Data output FD, RS-232C or GP-IB interface, Printer
Measurement range Fundamental frequency 10 Hz to 4.5 kHz
Harmonic Waveform Analysis Functions
Measurement method PLL locked sampling or external clock sampling method
A/ D resolution 12-bits
Window type Rectangular ( with gap between windows)
Crest factor 2.5 or less ( Voltage and Current)
PLL source Voltage ( U) , current ( I) or external synchronization of the selected measurement channel
External synchronization signal Input to a rear panel control terminal on the 3194 main unit
Input level: 1 V to 10 Vrms ( for sine waves)
Division function: 1/ 1 to 1/ 255
Measurement items RMS voltage, RMS current, effective power value, frequency, U peak, I peak
Harmonic waveform measurement items Harmonic level, Included percentage of harmonic wave, Phase angle of harmonic wave, Total harmonic distortion
Screen disolays List, bar-graph, vector and waveform displays
Other Functions
Wiring conversion ?  Y voltage conversion, Y ? voltage conversion
Sort function Sorts according to decreasing order of analysis, displays up to 50th order
Averaging function Index average with time constant of 1.5 sec
Power requirements 100/ 120/ 200/ 230 V AC, switched automatically , 50/ 60 Hz, 150 VA max.
Dimensions, mass 430 mm ( 16.93 in) W 150 mm ( 5.91 in) H 370 mm ( 14.57 in) D, 13 kg ( 458.6 oz) ( with options)
Supplied accessories Instruction Manual 1, Power cord 1, Connector 1
Tampilkan Lebih Banyak
karya mandiri instrument indonesia
karya mandiri instrument indonesia

Karya Mandiri Instrument Indonesia

PREMIUM GOLD 7 Tahun
Jl.Kramat III A No 29A, Lubang Buaya, Cipayung Jakarta Timur, Jakarta Timur
Indonesia 13810
Jakarta Timur
18 / 10 / 2019
Hubungi Kami

Detail Jual Alat Ukur Agen Industri Hioki 3194 Motor - Harmonic Hitester

CALL:

A.WIHARTA

081294124885

085778084789

087784022201

 

Info Produk

Basic specifications
Measurement lines Single-phase 2-wire, single-phase 3-wire, three-phase 3-wire, and three-phase 4-wire systems
Number of channels Up to 3 channels from input channels 1 to 6, depending on 3194 wiring mode
Data output FD, RS-232C or GP-IB interface, Printer
Measurement range Fundamental frequency 10 Hz to 4.5 kHz
Harmonic Waveform Analysis Functions
Measurement method PLL locked sampling or external clock sampling method
A/ D resolution 12-bits
Window type Rectangular ( with gap between windows)
Crest factor 2.5 or less ( Voltage and Current)
PLL source Voltage ( U) , current ( I) or external synchronization of the selected measurement channel
External synchronization signal Input to a rear panel control terminal on the 3194 main unit
Input level: 1 V to 10 Vrms ( for sine waves)
Division function: 1/ 1 to 1/ 255
Measurement items RMS voltage, RMS current, effective power value, frequency, U peak, I peak
Harmonic waveform measurement items Harmonic level, Included percentage of harmonic wave, Phase angle of harmonic wave, Total harmonic distortion
Screen disolays List, bar-graph, vector and waveform displays
Other Functions
Wiring conversion ?  Y voltage conversion, Y ? voltage conversion
Sort function Sorts according to decreasing order of analysis, displays up to 50th order
Averaging function Index average with time constant of 1.5 sec
Power requirements 100/ 120/ 200/ 230 V AC, switched automatically , 50/ 60 Hz, 150 VA max.
Dimensions, mass 430 mm ( 16.93 in) W 150 mm ( 5.91 in) H 370 mm ( 14.57 in) D, 13 kg ( 458.6 oz) ( with options)
Supplied accessories Instruction Manual 1, Power cord 1, Connector 1
Tampilkan Lebih Banyak