Back to Top

1
Hi, Guest!

  LOKASI :  Jakarta Timur

  AKTIVITAS :  15 hours ago

BAGIKAN :   

Bagikan :
Masukan Data Diri Anda
Nama harus diisi !
Email harus diisi !
Format email harus someone@example.com !
Kontak Kami  
ALAT LAB MURAH :EBRO,DAVIS WEATHER STATION,HANNA INSTRUMENT,EXTECH,EUTECH,IKA,GE DRUCK,BOECO,BESTSCOPE,FLUKE,DWYER,HACH,KYORITSU,OHAUS,MEMMERT,HIOKI,SCHOOT,KETT

Alat Ukur Alat Laboratorium,Hi 98121 Combo Ph/Orp/

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
1 Unit
Harga
CALL
Bagikan
:
Karya Mandiri Instrument Indonesia adalah supplier peralatan laboratorium baik eletronik maupun mekanik, serta berbagai macam instrument measurement, dengan didukung dari berbagai macam merk dari negara negara Eropa, US, dan beberapa negara di Asia seperti Korea, Japan dan Taiwan. Instrument yang kami sediakan seperti : Anemometer, Analitical Balance, Spectrophotometer, pHmeter, Laser survey, Micropipette, Peristaltic Pump, Flame photometer, Water bath heating cooling, Colorimeter, Water Strirer, Viscometer. Freezers, Refractometer, Polarimeter, Sound Level meter, Tachometer. Dll Kami juga menerima jasa service( Repair alat laboratorium/instrument, alat ukur, Alat kesehatan) dan kalibrasi untuk peralatan laboratorium sesuai kemampuan kami.

Info Produk dan Order Hubungi :
Mobile : 081294124885 // 085778084789 // 085104387311
Email   : karyamandiriinstrument@yahoo.com
Website : www. karyamandiri-instrument.com

Detail Jual Alat Ukur Alat Laboratorium,Hi 98121 Combo Ph/Orp/

CALL

A.WIHARTA

081294124885

085778084789

087784022201

 

Info Produk

Waterproof and it floats!
HANNA’ s exclusive cartridge pH and ORP electrode
Extendable cloth pH junction
Automatic Temperature Compensation
Automatic calibration
Battery % Level at startup and stability indicator
HOLD function

HI 98121 is a waterproof meter that measures pH, ORP and temperature. The housing of this tester has been completely sealed against humidity and are designed to float.

Electrode replacement with the stainless steel round connector means there are no pins to bend or break during replacement.

When the cloth junction becomes clogged and response time is sluggish, simply pull out 3 mm ( 1/ 8” ) to clear the clogging which will improve response time and stability.

The exposed stainless steel temperature sensor on these models facilitates faster and more accurate temperature measurement.

Order Information:
HI 98121 ( ORP/ pH) is supplied with HI 73127 pH electrode, HI 73128 electrode removal tool, batteries and instructions.

Range ORP ± 1000 mV
pH -2.00 to 16.00 pH
Temperature -5.0 to 60.0° C / 23.0 to 140.0° F
Resolution ORP 1 mV
pH 0.01 pH
Temperature 0.1° C / 0.1° F
Accuracy ORP ± 2 mV
pH ± 0.05 pH
Temperature ± 0.5° C / ± 1° F
Calibration ORP factory calibrated
pH automatic, one or two points with two sets of memorized buffers ( pH 4.01 / 7.01 / 10.01 or 4.01 / 6.86 / 9.18)
Temperature
Compensation Automatic for pH readings
Electrode HI 73127 replaceable pH electrode ( included) ; fixed ORP sensor
Battery Type / Life 1.5V ( 4) / approximately 250 hours of continuous use; auto-off after 8 minutes of non-use
Environment -5 to 50° C ( 23 to 122° F) ; RH max 100%
Dimensions 163 x 40 x 26 mm ( 6.4 x 1.6 x 1.0" )
Weight 100 g ( 3.5 oz.)
Tampilkan Lebih Banyak
karya mandiri instrument indonesia
karya mandiri instrument indonesia

Karya Mandiri Instrument Indonesia

PREMIUM GOLD 7 Tahun
Jl.Kramat III A No 29A, Lubang Buaya, Cipayung Jakarta Timur, Jakarta Timur
Indonesia 13810
Jakarta Timur
09 / 07 / 2020
Hubungi Kami

Detail Jual Alat Ukur Alat Laboratorium,Hi 98121 Combo Ph/Orp/

CALL

A.WIHARTA

081294124885

085778084789

087784022201

 

Info Produk

Waterproof and it floats!
HANNA’ s exclusive cartridge pH and ORP electrode
Extendable cloth pH junction
Automatic Temperature Compensation
Automatic calibration
Battery % Level at startup and stability indicator
HOLD function

HI 98121 is a waterproof meter that measures pH, ORP and temperature. The housing of this tester has been completely sealed against humidity and are designed to float.

Electrode replacement with the stainless steel round connector means there are no pins to bend or break during replacement.

When the cloth junction becomes clogged and response time is sluggish, simply pull out 3 mm ( 1/ 8” ) to clear the clogging which will improve response time and stability.

The exposed stainless steel temperature sensor on these models facilitates faster and more accurate temperature measurement.

Order Information:
HI 98121 ( ORP/ pH) is supplied with HI 73127 pH electrode, HI 73128 electrode removal tool, batteries and instructions.

Range ORP ± 1000 mV
pH -2.00 to 16.00 pH
Temperature -5.0 to 60.0° C / 23.0 to 140.0° F
Resolution ORP 1 mV
pH 0.01 pH
Temperature 0.1° C / 0.1° F
Accuracy ORP ± 2 mV
pH ± 0.05 pH
Temperature ± 0.5° C / ± 1° F
Calibration ORP factory calibrated
pH automatic, one or two points with two sets of memorized buffers ( pH 4.01 / 7.01 / 10.01 or 4.01 / 6.86 / 9.18)
Temperature
Compensation Automatic for pH readings
Electrode HI 73127 replaceable pH electrode ( included) ; fixed ORP sensor
Battery Type / Life 1.5V ( 4) / approximately 250 hours of continuous use; auto-off after 8 minutes of non-use
Environment -5 to 50° C ( 23 to 122° F) ; RH max 100%
Dimensions 163 x 40 x 26 mm ( 6.4 x 1.6 x 1.0" )
Weight 100 g ( 3.5 oz.)
Tampilkan Lebih Banyak