Back to Top

1
Hi, Guest!

  LOKASI :  Jakarta Timur

  AKTIVITAS :  9 hours ago

BAGIKAN :   

Bagikan :
Masukan Data Diri Anda
Nama harus diisi !
Email harus diisi !
Format email harus someone@example.com !
Kontak Kami  
ALAT LAB MURAH :EBRO,DAVIS WEATHER STATION,HANNA INSTRUMENT,EXTECH,EUTECH,IKA,GE DRUCK,BOECO,BESTSCOPE,FLUKE,DWYER,HACH,KYORITSU,OHAUS,MEMMERT,HIOKI,SCHOOT,KETT

Alat Ukur Laboratorium,agen Indonesia Hanna HI 9913

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
0 Unit
Harga
CALL
Bagikan
:
Karya Mandiri Instrument Indonesia adalah supplier peralatan laboratorium baik eletronik maupun mekanik, serta berbagai macam instrument measurement, dengan didukung dari berbagai macam merk dari negara negara Eropa, US, dan beberapa negara di Asia seperti Korea, Japan dan Taiwan. Instrument yang kami sediakan seperti : Anemometer, Analitical Balance, Spectrophotometer, pHmeter, Laser survey, Micropipette, Peristaltic Pump, Flame photometer, Water bath heating cooling, Colorimeter, Water Strirer, Viscometer. Freezers, Refractometer, Polarimeter, Sound Level meter, Tachometer. Dll Kami juga menerima jasa service( Repair alat laboratorium/instrument, alat ukur, Alat kesehatan) dan kalibrasi untuk peralatan laboratorium sesuai kemampuan kami.

Info Produk dan Order Hubungi :
Mobile : 081294124885 // 085778084789 // 085104387311
Email   : karyamandiriinstrument@yahoo.com
Website : www. karyamandiri-instrument.com

Detail Jual Alat Ukur Laboratorium,agen Indonesia Hanna HI 9913

 

CALL
A.WIHARTA
081294124885
085778084789
087784022201




HI 9913 is a 2-in-1 pH and conductivity controller engineered for dosage of fertilizer solutions in hydroponics and agriculture. HI 9913 measures pH from 0 to 14 and EC from 0 to 10 mS/ cm. Two separate set points can be user adjusted from 4 to 7 pH and 0 to 6 mS/ cm. The relays are activated when pH exceeds the set point or conductivity falls below the desired value. Two pumps or electrovalves can be wired directly to the controller and be powered through the terminal. The operator can adjust two independent proportional settings for pH and conductivity. The time cycle is adjustable from 0 to 90 seconds, while the proportional band is 0 to 2 for both pH and EC. A matching pin/ ground probe can be connected to the appropriate terminals to eliminate interference and prolong the pH electrode' s life. HI 9913 provides for an alarm relay which is activated in several circumstances. These include when the pH is below the set point by the operator-adjustable threshold of 0.5 to 2.5 pH, or EC exceeds the set point by a value in the 0.5 to 2.5 mS/ cm range. The alarm goes off if the pH and/ or conductivity are not corrected within the operator-determined time frame of 1 to 10 minutes. The alarm can be turned off during maintenance. Fertilization status can be ascertained from a distance through dosage and alarm LED' s. HI 9913 accepts pH electrodes with BNC and conductivity probes with DIN connectors.

Tampilkan Lebih Banyak
karya mandiri instrument indonesia
karya mandiri instrument indonesia

Karya Mandiri Instrument Indonesia

PREMIUM GOLD 7 Tahun
Jl.Kramat III A No 29A, Lubang Buaya, Cipayung Jakarta Timur, Jakarta Timur
Indonesia 13810
Jakarta Timur
12 / 07 / 2020
Hubungi Kami

Detail Jual Alat Ukur Laboratorium,agen Indonesia Hanna HI 9913

 

CALL
A.WIHARTA
081294124885
085778084789
087784022201




HI 9913 is a 2-in-1 pH and conductivity controller engineered for dosage of fertilizer solutions in hydroponics and agriculture. HI 9913 measures pH from 0 to 14 and EC from 0 to 10 mS/ cm. Two separate set points can be user adjusted from 4 to 7 pH and 0 to 6 mS/ cm. The relays are activated when pH exceeds the set point or conductivity falls below the desired value. Two pumps or electrovalves can be wired directly to the controller and be powered through the terminal. The operator can adjust two independent proportional settings for pH and conductivity. The time cycle is adjustable from 0 to 90 seconds, while the proportional band is 0 to 2 for both pH and EC. A matching pin/ ground probe can be connected to the appropriate terminals to eliminate interference and prolong the pH electrode' s life. HI 9913 provides for an alarm relay which is activated in several circumstances. These include when the pH is below the set point by the operator-adjustable threshold of 0.5 to 2.5 pH, or EC exceeds the set point by a value in the 0.5 to 2.5 mS/ cm range. The alarm goes off if the pH and/ or conductivity are not corrected within the operator-determined time frame of 1 to 10 minutes. The alarm can be turned off during maintenance. Fertilization status can be ascertained from a distance through dosage and alarm LED' s. HI 9913 accepts pH electrodes with BNC and conductivity probes with DIN connectors.