Koehler K13900 Cleveland Open-Cup Flash Tester

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
0 Unit

Harga

CALL
Karya Mandiri Instrument Indonesia adalah supplier peralatan laboratorium baik eletronik maupun mekanik, serta berbagai macam instrument measurement, dengan didukung dari berbagai macam merk dari negara negara Eropa, US, dan beberapa negara di Asia seperti Korea, Japan dan Taiwan.

Detail Koehler K13900 Cleveland Open-Cup Flash Tester


CALL:
A.WIHARTA
081294124885
085778084789
087784022201


Karya Mandiri Instrument indonesia
adalah supplier peralatan laboratorium baik eletronik maupun mekanik, serta berbagai macam instrument measurement, dengan didukung dari berbagai macam merk dari negara negara Eropa, US, dan beberapa negara di Asia seperti Korea, Japan dan Taiwan. Instrument yang kami sediakan seperti : Anemometer, Analitical Balance, Spectrophotometer, pHmeter, Laser survey, Micropipette, Peristaltic Pump, Flame photometer, Water bath heating cooling, Colorimeter, Water Strirer, Viscometer. Freezers, Refractometer, Polarimeter, Sound Level meter, Tachometer. Dll

Kami juga menerima jasa service dan kalibrasi untuk peralatan laboratorium sesuai kemampuan kami.

 

Test Method For flash and fire points of all petroleum products, except fuel oils and those having an open cup flash below 79° C ( 175° F) . Features and Benefits • Conforms to ASTM D92 and related specifications • For flash points above 79° C ( 175° F) K13900 Cleveland Open-Cup Flash Tester Determines flash and fire points by the Cleveland Open-Cup method. Consists of test flame applicator, brass test cup, thermometer support, heating plate and electric heater. Applicator is precisely aligned per specifications and pivots for test flame application at specified temperature intervals. Hinged thermometer support raises to facilitate placement and removal of test cup. Adjust flame size using built-in needle valve and comparison bead. Equipped with a 1000W nickel-chromium heater with stepless variable heat control for accurate repeat setting of temperature rate of rise per specifications. Heater unit is enclosed in a stainless steel housing with cooling vents. Test flame applicator and thermometer support are constructed of machined nickel plated brass. Specifications Conforms to: ASTM D92, D6074, D6158; AASHTO T48; ANS Z-11.6; IP 36; ISO 2592; DIN 51376; FTM 791-1103, FTM 141-4294 Electrical Requirements 115V 50/ 60Hz, Single Phase, 6.5A 220-240V 50/ 60Hz, Single Phase, 3.4A Included Accessories Brass Test Cup Dimensions lxwxh, in.( cm) 10x5.5x14 ( 25x14x36) Net Weight: 8.5 lbs ( 3.9kg) Shipping Information Shipping Weight: 12 lbs ( 5.4kg) Dimensions: 1.5 Cu. ft. Ordering Information Catalog Number Product Description Electrical Requirements K13900 Electrically Heated Model 115V 50/ 60Hz K13990 Electrically Heated Model 220-240V 50/ 60Hz Accessories Catalog Number Product Description Temperature Range 250-000-11F ASTM 11F Thermometer 20 to 760° F 250-000-11C ASTM 11C Thermometer -6 to + 400° C K14000 Cleveland Open Flash Cup Precision machined brass with heat resistant handle

Tampilkan Lebih Banyak